Time:12/24/2018 1:39:46 PMauthor:source:
Replacement of construction lift magnet seat
1. Remove the protective cover and mechanical release handle, remove the cable and cable clamp, and position and adjust the position mark of the device to reset when reloading;
2. Use a hex wrench to remove the complete set and the brake spring, remove the nut, remove the cover and the electromagnet holder, and install the electromagnet holder;
3. Remove the screw and magnet working surface;
4. Remove the four spring rings, remove the armature and remove the spring. Note: Do not pull the sleeve out of the cone.
5. Remove the inspection from the magnet holder and install a new magnet holder. Be careful not to pull the sleeve out of the cone and install the spring.
6. Place the armature on the outer casing to adapt the slot to the coil cable and the spring coil;
7. Press the magnet rotor, install the cover screw, and ensure that the magnet and armature between the gaps are even, and the size is 1.6 ± 0.1 mm.
8. Place the magnet and the armature on the fixing bolts. The cable trough is fixed on the slot on the fixed brake disc;
9. Install the end cap to the fixing bolt, tighten the nut, slowly, prevent the armature on the magnet and the bolt; install the brake spring, adjust the sleeve, adjust the sleeve according to the position recorded in step 1, the coil connection cable, and the brake The inspection work is normal;
10. Install the protective cover and release handle to ensure that you do not tighten.